Product

Company

Support

Contact us

Get a quote

Sample preparation, simplified.

Sample preparation, simplified.

Sample preparation, simplified.

Manta works with a wide range of clinical diagnostic samples, offering precise and reliable results with every run. Its compact design and low-throughput capacity introduces a crucial feature for modern molecular labs:

Manta works with a wide range of clinical diagnostic samples, offering precise and reliable results with every run. Its compact design and low-throughput capacity introduces a crucial feature for modern molecular labs:

Manta works with a wide range of clinical diagnostic samples, offering precise and reliable results with every run. Its compact design and low-throughput capacity introduces a crucial feature for modern molecular labs:

The Ability to automate

regardless of the sample load.

The Ability to automate

regardless of the sample load.

The Ability to automate

regardless of the sample load.

Seamless sample preparation, designed for your lab

Seamless sample preparation,

designed for your lab

Seamless sample preparation,

designed for your lab

Pre-filled and ready to go

Pre-filled and ready to go

Manta operates on pre-filled cartridges to make your workflow smooth sailing. Just peel off the seal, add your sample, and you're ready to start!

Manta operates on pre-filled cartridges to make your workflow smooth sailing. Just peel off the seal, add your sample, and you're ready to start!

Manta operates on pre-filled cartridges to make your workflow smooth sailing. Just peel off the seal, add your sample, and you're ready to start!

Flexible, for your lab

Flexible, for your lab

Whether you need to run just 1 sample or up to 32 samples, Manta adapts to your lab's workload. It’s perfect for labs of all sizes, maximizing efficiency without wasting reagents or time.

Whether you need to run just 1 sample or up to 32 samples, Manta adapts to your lab's workload. It’s perfect for labs of all sizes, maximizing efficiency without wasting reagents or time.

Whether you need to run just 1 sample or up to 32 samples, Manta adapts to your lab's workload. It’s perfect for labs of all sizes, maximizing efficiency without wasting reagents or time.

Handles input volumes

from µL to mL

Handles input volumes

from µL to mL

With Manta, you can work with starting sample volumes ranging from 100 μl to 4 mL. This makes it ideal for labs handling different sample types and volumes

With Manta, you can work with starting sample volumes ranging from 100 μl to 4 mL. This makes it ideal for labs handling different sample types and volumes

With Manta, you can work with starting sample volumes ranging from 100 μl to 4 mL. This makes it ideal for labs handling different sample types and volumes

Built with your

workspace in mind

Built with your

workspace in mind

Manta is about 4x smaller than other automation systems. It is designed efficiently to take up less space on your workbench 

Manta is about 4x smaller than other automation systems. It is designed efficiently to take up less space on your workbench 

Manta is about 4x smaller than other automation systems. It is designed efficiently to take up less space on your workbench 

Quick run time

Quick run time

Manta operates on pre-filled cartridges to make your workflow smooth sailing. Just peel off the seal, add your sample, and you're ready to start!

Manta operates on pre-filled cartridges to make your workflow smooth sailing. Just peel off the seal, add your sample, and you're ready to start!

Manta operates on pre-filled cartridges to make your workflow smooth sailing. Just peel off the seal, add your sample, and you're ready to start!

After years of developing and perfecting magnetic nanoparticles for genomic workflows, we have adapted our beads to an automated solution to help you achieve your extraction goals in record time.

After years of developing and perfecting magnetic nanoparticles for genomic workflows, we have adapted our beads to an automated solution to help you achieve your extraction goals in record time.

Manta uses this magnetic bead-based technology to purify DNA, RNA,

and cell-free DNA.

Manta uses this magnetic bead-based technology to purify DNA, RNA, and cell-free DNA.

The device operates on cartridges that feature distinct wells filled with beads and buffers. The before magnetic rods collect the beads and transfer them to subsequent wells, taking the sample through lysis, binding, washing, and elution–ultimately providing you with high molecular weight nucleic acid.

Our

Certifications

In vitro diagnostics

Manta's IVD certification ensures that our product meets the highest standards for in vitro diagnostic use, providing reliability and confidence in laboratory results.

Cambri-Benga-KA/M/IVD/-17175

International Organization

for Standardization

We are proud to hold ISO 13485 certification, demonstrating our commitment to quality management in the design and manufacturing of medical devices.

Experience

the Manta

Experience

the Manta

Manta automates extractions to fit seamlessly into your lab’s workflow. Watch how simple it is to load samples with pre-filled cartridges, customize settings for your sample size, and start a run with just a few taps. Take a peek at how it works in this quick demo video:

Manta automates extractions to fit seamlessly into your lab’s workflow. Watch how simple it is to load samples with pre-filled cartridges, customize settings for your sample size, and start a run with just a few taps. Take a peek at how it works in this quick demo video:

Book your demo

Book your demo

Book your demo

How do we compare

Features

Samples per run

Minimum sample capacity

Sample types compatible

cfDNA extraction

Extraction time

Remote monitoring

Touchscreen interface

Consumable type

Dimensions


Library clean-up available with software updates

Capable of eluting in a barcoded tube

Manta

Any between 1 & 32

1

1 - 32

Yes

27 mins

Yes

Yes

Pre-filled cartridge

26.2cm x 43.5cm x 28.2cm (HxWxD)

Yes

Yes

Company Q

6 or 12

6

FFPE not compatible

No

25 mins

No

No

Deep-well plate

34cm x 40cm x 46cm (HxWxD)

No

No

Company T

Any between 1 & 24

1

1 - 24

Yes

35 mins

Yes

Yes

Pre-filled cartridge

57.5cm x 72cm x 56cm (HxWxD)

No

No

How do we compare

Features

Samples per run

Minimum sample capacity

Sample types compatible

cfDNA extraction

Extraction time

Remote monitoring

Touchscreen interface

Consumable type

Dimensions


Library clean-up available with software updates

Capable of eluting in a barcoded tube

Manta

Any between 1 & 32

1

1 - 32

Yes

27 mins

Yes

Yes

Pre-filled cartridge

26.2cm x 43.5cm x 28.2cm (HxWxD)

Yes

Yes

Company Q

6 or 12

6

FFPE not compatible

No

25 mins

No

No

Deep-well plate

34cm x 40cm x 46cm (HxWxD)

No

No

Company T

Any between 1 & 24

1

1 - 24

Yes

35 mins

Yes

Yes

Pre-filled cartridge

57.5cm x 72cm x 56cm (HxWxD)

No

No

How do we compare

Features

Samples per run

Minimum sample capacity

Sample types compatible

cfDNA extraction

Extraction time

Remote monitoring

Touchscreen interface

Consumable type

Dimensions


Library clean-up available with software updates

Capable of eluting in a barcoded tube

Manta

Any between 1 & 32

1

1 - 32

Yes

27 mins

Yes

Yes

Pre-filled cartridge

26.2cmx43.5cmx28.2cm (HxWxD)

Yes

Yes

Company Q

6 or 12

6

FFPE not compatible

No

25 mins

No

No

Deep-well plate

34cm x40cmx46cm (HxWxD)

No

No

Company T

Any between 1 & 24

1

1 - 24

Yes

35 mins

Yes

Yes

Pre-filled cartridge

57.5cm x 72cm x 56cm (HxWxD)

No

No

Technical specifications

Measurements

Dimensions

43.5 x 28.2 x 26.7 cm [L x B x H]

Weight

18kg

Processing compatibility

Extraction method

Magnetic bead-based technology

Biospecimen compatibility

Whole blood, tissue, plasma, FFPE blocks, virus, bacteria, cell cultures, DBS cards, plasmid, saliva, sputum, swabs, pus, amniotic fluid, CSF, VTM, endotracheal aspirates, urine, CSF, pleural fluid, CVS, peritoneal fluid, synovial fluid, and more.

Starting sample volume

100µL - 4mL

Elution volume

50µL - 200µL 

Optional: Elute in a barcoded storage tube

Consumables

Cartridges

1 cartridge for 1 sample, re-filled, non-reusable

Plastic comb

One for eight samples; non-reusable

Starting sample volume

100µL - 4mL

Buffers

Pre-filled; components differ according to sample type; non-re-usable

Operations

Operating conditions

15°C - 40°C; indoor use only

UC System

UVC lamp

Heating temperature

Up to 85° C

Processing time

≈30 minutes, varies based on sample type

Display interface

7" inch touchscreen displa

Mains power supply

240 V

Power consumption

800 Watts

UPS Recommendation

1100 VA

Technical specifications

Measurements

Dimensions

43.5 x 28.2 x 26.7 cm [L x B x H]

Weight

18kg

Processing compatibility

Extraction method

Magnetic bead-based technology

Biospecimen compatibility

Whole blood, tissue, plasma, FFPE blocks, virus, bacteria, cell cultures, DBS cards, plasmid, saliva, sputum, swabs, pus, amniotic fluid, CSF, VTM, endotracheal aspirates, urine, CSF, pleural fluid, CVS, peritoneal fluid, synovial fluid, and more.

Starting sample volume

100µL - 4mL

Elution volume

50µL - 200µL 

Optional: Elute in a barcoded storage tube

Consumables

Cartridges

1 cartridge for 1 sample, re-filled, non-reusable

Plastic comb

One for eight samples; non-reusable

Starting sample volume

100µL - 4mL

Buffers

Pre-filled; components differ according to sample type; non-re-usable

Operations

Operating conditions

15°C - 40°C; indoor use only

UC System

UVC lamp

Heating temperature

Up to 85° C

Processing time

≈30 minutes, varies based on sample type

Display interface

7" inch touchscreen displa

Mains power supply

240 V

Power consumption

800 Watts

UPS Recommendation

1100 VA

Technical specifications

Measurements

Dimensions

43.5 x 28.2 x 26.7 cm [L x B x H]

Weight

18kg

Processing compatibility

Extraction method

Magnetic bead-based technology

Biospecimen compatibility

Whole blood, tissue, plasma, FFPE blocks, virus, bacteria, cell cultures, DBS cards, plasmid, saliva, sputum, swabs, pus, amniotic fluid, CSF, VTM, endotracheal aspirates, urine, CSF, pleural fluid, CVS, peritoneal fluid, synovial fluid, and more.

Starting sample volume

100µL - 4mL

Elution volume

50µL - 200µL 

Optional: Elute in a barcoded storage tube

Consumables

Cartridges

1 cartridge for 1 sample, re-filled, non-reusable

Plastic comb

One for eight samples; non-reusable

Starting sample volume

100µL - 4mL

Buffers

Pre-filled; components differ according to sample type; non-re-usable

Operations

Operating conditions

15°C - 40°C; indoor use only

UC System

UVC lamp

Heating temperature

Up to 85° C

Processing time

≈30 minutes, varies based on sample type

Display interface

7" inch touchscreen displa

Mains power supply

240 V

Power consumption

800 Watts

UPS Recommendation

1100 VA

Find the kit for your workflows

Find the kit for your workflows

Catalog number

Product name

Compatible sample types

CBWM068.64

Cambrian Whole Blood gDNA Isolation Kit

Whole blood

Cell cultures

Bone marrow

CBWM096.64

Cambrian Tissue gDNA Isolation Kit

Fresh/frozen tissue

Pus

Sputum

CVS

Urine

PoC

Pleural fluid

CBWM100.64

Cambrian FFPE DNA Isolation Kit

FFPE Tissue

CBWM30.64

Cambrian Viral DNA/RNA Isolation Kit

Plasma

Serum

VTM

CBWM085.64

Cambrian Saliva DNA Isolation Kit

Buccal swabs

Saliva

CBWM137.64

Cambrian Cord Blood gDNA Isolation Kit

Cord blood

CBWM136.64

Cambrian DBS gDNA Isolation Kit

DBS cards

CBWM070.64

Cambrian Blood RNA Isolation Kit

Blood

CBWM008-T

8 Tip combs for Manta

-

CBWM009-BT

Cambrian 2D-2ML tube.

-

CBWM010-R

Cambrian DBS gDNA Isolation Kit

-

Find the kit for your workflows

FAQs

Is Manta an open system?

What does the kit include?

Can cartridges be reused?

Can the combs be reused?

What’s the process for making a purchase?

Can Manta run different sample types together?

What is the average run time?

How does Manta control contamination?

Where is Manta manufactured?

FAQs

Is Manta an open system?

What does the kit include?

Can cartridges be reused?

Can the combs be reused?

What’s the process for making a purchase?

Can Manta run different sample types together?

What is the average run time?

How does Manta control contamination?

Where is Manta manufactured?

FAQs

Is Manta an open system?

What does the kit include?

Can cartridges be reused?

Can the combs be reused?

What’s the process for making a purchase?

Can Manta run different sample types together?

What is the average run time?

How does Manta control contamination?

Where is Manta manufactured?

See Manta in action

See Manta in action

See Manta in action

Schedule a demo with us and see how Manta can make your workflows more efficient.

Schedule a demo with us and see how Manta can make your workflows more efficient.

Schedule a demo with us and see how Manta can make your workflows more efficient.

Schedule your demo now

Schedule your demo now

Schedule your demo now